VRLA AGM: design life 7-10 years
VRLA GEL: design
life 12 years
VRLA GEL 2 Volt cells: design life 20 years
The AGM range has very low internal resistance making
them particulary suitable for high current discharge
applications such as for inverters, thrusters and winches as
well as engine starting.
The GEL model range offer best
deep cycle durability and overall longer life.
The
use of high purity materials and lead calcium grids ensure
that for both AGM and GEL products have particulary low self
discharge so that they will not go flat during long periods
without charge.
Both ranges are supplied with M8
drilled, flat copper terminals ensuring best possible
connection contact and eliminating the need for battery
terminals. Manufactured under ISO 9001 quality standards,
they are compliant with both CE and UL specifications in ABS
fileproof containers and come with Victron's 2 year
world-wide warranty.
Tubular positive platesRobust
tubular plates consisting of a lead calcium antimony alloy,
optimized for high corrosion resistances.
Pasted negative platesGrid plate construction
consisting of low antimony with long-life expander material.
SeparatorsMicroporous and ro- bust,
for electrical separation of the positive and negative
plates and opti- mized for low internal resistance.
ContainerHigh impact, transparent
SAN (Styrol-Acryl-Nitril)
Safety Vents
Cells incorporate flame retardant ceramic plugs that filter
out any drops of electrolyte from the escaping gases
preventing any errant spark or flame from entering the
battery.
PolesScrew connection
for easy and safe assembly and maintenance-free connection
with excellent conductivity.
Post seals
Extremely high integrity post seal design to prevent
electrolyte.
ConnectorsFlexible,
fully insulated cable connectors screwed to the termi- nal
with an insulated screw having a probe hole
on the top
for electrical measurement.
Standard and
ComplianceDIN 40736 part 1
DIN 40737 part 2
IEC 896 part 1
Applications•
Telecommunications
• Emergency lighting
• Microwave
radio systems
• Power generation plants
•
Photovoltaics
S
pecifications•
Very high operationally reliability under rough operating
conditions
• Low maintenance due to reduced antimony in
the alloy and high elec- trolyte reserve
• Nominal
capacity 50–3350 Ah C10
• 20 years at 20°C (80% remaining
capacity from C10)
• Also designed for cyclic
applications
• Also available in dry charged condition
with separate electrolyte
• Low gassing due to
PbSb1.6SnSe alloy (EN 50272-2)
• Conforms to DIN 40 736
and DIN 40 737 T3
• Electrolyte: diluted sulphuric acid
dN = 1.25 kg/l
• Optimized plate design produces
increased capacities compared to DIN
• Completely
recyclable