Home Meanwell Delta Puls Sunpower Archcorp Cotek Manson Kerio 
   

Meanwell-Summary
Meanwell-Summary

Open Frame Switching Power Supply: Wattage:30W~200W/ No. of Output:1,2,3,4

* PCB type, non-PFC for small wattage models
* Comply with medical safety certificates
* Low leakage current suitable for non-patient contact medical equipments

30W Single Output for Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage / Over temperature. Fixed switching frequency at 100KHz. Low cost. High reliability. 45W Single Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. Fixed switching frequency at 45KHz. 45W Dual Output Medical Type. Universal AC input / Full range. Protections:Short circuit/Over load/Over voltage. Cooling by free air convection. 100% full load burn-in test. Fixed switching frequency at 45KHz. 45W Triple Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. Fixed switching frequency at 45KHz. 100% full load burn-in test
60W Single Output Medical Type. 4"x2" miniature size. Universal AC input/Full range. Low leakage current<200uA. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. No load power consumption<0.75W. Fixed switch frequency at 100KHz. 60W Dual Output Medical Type. 4"x2" miniature size. Universal AC input/Full range. Low leakage current<200uA. Protections: Short circuit / Over load / Over voltage. Cooling by free air convection. Fixed switch frequency at 100KHz. 60W Triple Output Medical Type. 4"x2" miniature size. Universal AC input / Full range. Low leakage current<200uA. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. Fixed switch frequency at 100KHz. 65W Single Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. 100% full load burn-in test. Fixed switching frequency at 45KHz.
65W Dual Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. 100% full load burn-in test. Fixed switching frequency at 45KHz 65W Triple Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage. Cooling by free air convection. Fixed switching frequency at 45KHz. 100% full load burn-in test. 75W Single Output Medical Type. Universal AC input/Full range. Low leakage current<200uA. Protections: Short circuit / Overload / Over voltage. Free air convection for rated power and 23.5CFM forced air convection for peak load. No load power consumption<0.75W 75W Dual Output Medical Type. Universal AC input/Full range. Low leakage current<200uA. Free air convection for rated power and 23.5CFM forced air
convection for peak load. Fixed switching frequency at 65KHz.
75W Triple Output Medical Type. Universal AC input / Full range. Low leakage current<200uA. Protections: Short circuit / Overload / Over voltage. Free air convection for rated power and 23.5CFM forced air
convection for peak load. Fixed switching frequency at 65KHz.
1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage. UL60601-1 medical safety approved. With power good and fail signal output (Optional). 100% full load burn-in test. Fixed switching frequency at 45KHz. 1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage. UL60601-1 medical safety approved. With power good and fail signal output (Optional). Fixed switching frequency at 45KHz. 1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage. UL60601-1 medical safety approved. With power good and fail signal output (Optional). 100% full load burn-in test. Fixed switching frequency at 45KHz.
1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage. UL60601-1 medical safety approved. With power good and fail signal output (Optional). 100% full load burn-in test. Fixed switching frequency at 45KHz. 160W Single Output Medical Type. Universal AC input / Full range. Built-in active PFC function. 5"x3" compact size. Free air convection for 110W and 160W with 20.5 CFM forced air. With power good and fail signal output. Built-in remote sense function for 5~15V. No load power consumption under 0.75W by PS-ON control (Optional). 160W Dual Output Medical Type. Universal AC input / Full range. Built-in active PFC function. 5"x3" compact size. Free air convection for 100W and 150W with 20.5 CFM forced air. With power good and fail signal output. Standby 5V@0.8A with Fan/0.6A without Fan (Optional). 160W Triple Output Medical Type. Universal AC input / Full range. Built-in active PFC function. 5"x3" compact size. With power good and fail signal output. No load power consumption under 0.75W by PS-ON control (G model). Standby 5V@0.8A with fan, @0.6A without fan (G model).
1~4 Output Medical Type. 1~4 Output Medical Type. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage / Over temperature. Free air convection for 140W and forced air convection for 200W. UL60601-1 medical safety approved. With power good and fail signal output. Built-in remote ON-OFF control. Built-in remote sense function. 1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage / Over temperature. Free air convection for 140W and forced air convection for 200W. UL60601-1 medical safety approved. With power good and fail signal output. Built-in remote ON-OFF control 1~4 Output Medical Type. Universal AC input / Full range. Low leakage current <180 A. Protections: Short circuit / Overload / Over voltage / Over temperature. Free air convection for 140W and forced air convection for 200W. UL60601-1 medical safety approved. With power good and fail signal output. Built-in remote ON-OFF control. Fixed switching frequency at 100KHz. 1~4 Output Medical Type. Universal AC input / Full range. Protections: Short circuit / Overload / Over voltage / Over temperature. Free air convection for 140W and forced air convection for 200W. UL60601-1 medical safety approved. Fixed switching frequency at 100KHz. Built-in remote sense function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mobile Numbers

ENCLOSED AC/DC CONVERTERS

G3 Series
G2 Series
NE-Series 
PFC Series
Modular Series
DIN Series
OPEN FRAME SWITCHING P/S
On Board Type
General PCB
Medical Type
EXTERNAL SWITCHING P/S
Desktop
Medical Desktop
Wall Mounted
SPECIFIC PURPOSE P/S
Video Game
ATX
DC/DC CONVERTERS
Module Type
On board Type
PCB Type
Enclosed Type
DC/AC INVERTERS
Modified Sine wave
True Sine wave
IP65 / IP67 Power supplies
LED Lighting series
SHORT FORM CATALOGUE

April 2011
LED Power Supply 2011

DIN rail catalogue
Power supplie catalogue
 
MW catalogue 2010
 
 
 
Desktop catalogue
 
Inverter catalogue
 
Enclosed single output catalogue
 
Open frame catalogue
 
Dual enclosed catalogue
 
Open Frame catalogue