The BMV-600S and BMV-602S are our newest high precision
battery monitors. The essential function of a battery
monitor is to calculate ampere-hours consumed and the state
of charge of a battery. Ampere-hours consumed are calculated
by integrating the current flowing in or out of the battery.
- Highest resolution: 10mA (0,01A) with 500A shunt.
Lowest current consumption: 1mA.
Easiest to wire: the
BMV-600 comes with shunt, 10 meter RJ 12 UTP cable and 2
meter battery cable with fuse. No other components
needed.
Easiest to install: separate front bezel for
square or round appearance; ring for rear mounting and
screws for front mounting.
The BMV-602 has a second voltage measurement input. This
input can for example be used to measure the voltage of a
starter battery
Precision monitoringThe essential
function of a battery monitor is to calculate ampere-hours
consumed and the state of charge of a battery. Ampere-hours
consumed is calculated by integrating the current flowing in
or out of the battery. In case of a constant current, this
integration is equivalent to current multiplied by time. A
discharge current of 10A during 2 hours, for example,
amounts to 20Ah consumed. All our battery
monitors are
based on a powerful microprocessor, programmed with the
algorithms needed for precision monitoring.
Standard information and alarms
- Battery
voltage (V).
- Battery charge/discharge current (A).
-
Ampere-hours consumed (Ah).
- State of charge (%).
-
Time to go at the current rate of discharge.
- Visual and
audible alarm: over- and under voltage, and/or battery
discharged.
- Programmable alarm or generator start
relay.
BMV 600S: low cost ultra high
resolution monitor
- Highest resolution: 10mA
(0,01A) with 500A shunt.

- Can be used with 50, 60 or
100mV shunts, current rating from 100A to 1000A
- Lowest
current consumption: 4mA @12V and 3mA @ 24V.
- Easiest to
wire: the BMV 600S comes with shunt, 10 meter RJ 12 UTP
cable and 2 meter battery cable with fuse; no other
components needed.
- Easiest to install: separate front
bezel for square or round appearance; ring for rear mounting
and screws for front mounting.
- Broadest voltage range:
9.5 – 95 VDC without prescaler needed.
- Communication
port (Isolated RS232 interface is needed to connect to a
computer)
BMV 602S: (two batteries)
In addition to all the features of the BMV600S, the BMV602S
can measure the voltage of a
second battery.A version
with a black front bezel (BMV 602S Black) is also available.
BMV 602HS: (70 to 350VDC voltage range)No prescaler
needed. Note: suitable for systems with grounded minus only
(battery monitor is not
isolated from shunt).
Optional Isolated RS232 communication interface and
software
(for all BMV models) Displays all
information on a computer and loads charge/discharge data in
an Excel
file for graphical display.
|
VE.Net Battery Controller |
 |
VE.Net Battery
Controller: any number of batteries- One VE.Net panel or
Blue Power panel will connect to any number of battery
controllers.
- Comes with 500A/50mV shunt and can be
programmed for 50, 60 or 100mV shunts, current rating from
100A to 10.000A.
- With use, abuse and data memory.
-
Temperature sensor and connection kit included.
No more guessing
Identifying exactly how
much energy is left in a battery is not easy. A voltmeter is
useful but will only indicate that the battery is flat when
it is too late. In order to keep an accurate record of what
is stored in a battery it is necessary to keep account of
all the factors that affect it and this is a complex matter.
Once a reliable reading of the state of charge of the
battery is available however, life starts to get an awful
lot less complicated.
No more nasty surprises with
batteries going flat unexpectedly and it becomes possible to
manage batteries on fact rather than
guess work. It is
amazing how much power you can have with a little extra
knowledge!
Accurate and reliable
The data used by the VE.Net Battery Controller is monitored
with an accuracy better than 0,5% and, employing Peukert’s
formula, account is taken of the reduction of effective
capacity of the battery when the discharge current
increases. An optional temperature sensor helps to further
improve accuracy where wide temperature variation is
expected.
Standard information-
Battery voltage (V)
- Battery charge/discharge current
(A)
- Consumed Ampere-hours (Ah)
- State of charge of
the battery (%)
- Time to go (until the battery it flat
at the present rate of discharge)
- Battery temperature
Start your generatorThe VE.Net
Battery Controller has a relay that you can use to start
your generator or to activate an external alarm for remote
monitoring. With the built in and adjustable hysteresis for
State of Charge (%) you can program when to close and open
the contacts at your desired levels.
Adjustable AlarmsThe Battery Controller can
generate alarms on:
- Low voltage
- High voltage
-
State of charge
Intelligent communication to other VE.Net
enabled devices The data from the Battery monitor will be
available to all devices on the VE.Net network. The VE.Net
Generator Module can use it to start and stop the generator.
VE.Net enabled Battery Chargers can use it to optimize the
charge currents to eliminate influences from a varying load.
Historic data
To enable you to
interrogate;
- Deepest discharge (Ah)
- Depth of last
discharge (Ah)
- Number of cycles
- Average discharge
(Ah)
- Number of full discharges
- Cumulative Battery
Amp Hours (Ah)
- Maximum Battery Volts (V)
- Minimum
Battery Volts (V)
- Days since last full charge
Variable shunt parametersThe VE.Net
Battery Controller can be used with any shunt as an
alternative to the standard 500A/50mv shunt included with
the package. In the menu you can setup the full current
rating of the shunt (10 - 50000A) and the according voltage
in millivolts (10 - 50 mV).
High voltage VE.Net Battery
Controller: 70 to 350VDCNo prescaler
needed. Note: RJ45 connectors are galvanically isolated from
Controller and shunt.
|
VE.Net Global Remote |
 |
Victron Global RemoteThe Global
Remote is a modem which sends alarms, warnings and system
status reports to cellular phones via text messages (SMS).
It can also log data from
Victron Battery Monitors, MultiPlus units,
Quattro’s and Inverters to a website through a GPRS
connection. Access to this
website is free of charge.
Victron Global Remote to BMV 602
Connection Kit
Cable kit required to connect the BMV 602
and the Victon Global Remote. BMV 602 Data Link included.